Pagina 1 - Owner’s Manual

Nº32ReferencePhono ModulesOwner’s ManualMadrigal Audio LaboratoriesR

Pagina 2

10UnpackingWarning! Do not attempt to use your Nº32 Reference Phonomodules unless your Nº32 Controller is using version1.03 (or greater) of its operat

Pagina 3 - Important Safety Instructions

11Operating VoltageThe Nº32 Reference Preamplifier is set at the factory (internally) for100V, 120V, 230V, 220V, or 240V AC mains operation @ 50 or 60

Pagina 4

12Installing the Nº32 ReferencePhono Preamplifier ModulesImportant! Installation of the Nº32 Reference Phono PreampllifierModules should be done by a

Pagina 5 - Table of Contents

13material needed The following materials and tools are needed to perform the installa-tion of the Nº32 Phono modules into the Nº32 Preamplifier:1 – N

Pagina 6 - Nº32 Reference Preamplifier

143. Remove the two screws from rear bottom of Nº32 Preampli-fier top cover that hold it in place (using the 3⁄32” hex keysupplied with the Nº32).Thes

Pagina 7

155. Peel off the protective film covering the copper strip on theend of the wrist strap, and attach it so that the copper stripcontacts the chassis o

Pagina 8 - TONE ARM GROUND

16this , not Warning: The cables must lie flat against phono preamp topcover to slide in to Nº32 preamp.8. Gently slide the left phono preamp mod

Pagina 9 - RIAA equalization

1711. Carefully lift connector ends of cables out of holes in phonopreamp top cover.Being careful to avoid catching the connectors on the edges of the

Pagina 10 - Unpacking

18(closeup)13. Remove your ESD wrist strap from the chassi and from yourwrist.It would hinder your replacing the top cover, next.14. Replace Nº32 prea

Pagina 11 - Operating Voltage

19Customizing Your Nº32setup overview The Nº32 Preamplifier has many provisions for custom-tailoring thesystem’s operation to match your preferences.

Pagina 12 - Phono Preamplifier Modules

CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DONOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.REFER S

Pagina 13

20Set Phono 1Name= PH/MC 1Ph Gain= +60Gain= +12 dBOffset= 0.0Bal= <-0.0->20Hz HPF=ONR Load=100C Load=.01uFSet Phono 2Name= PH/MM 2Ph Gain= +40G

Pagina 14 - 32” hex key

21between the output level of a given source and thepreamplifier’s gain structure.• Offset— automatic volume adjustments implementedwhenever switching

Pagina 15 - 64” hex)

22The Ph Gain selection should be made prior to the gain adjustmentoutlined below, as appropriate for your cartridge type. Otherwise youmay end up att

Pagina 16 - 32” hex key)

23setting the balance The balance (Bal) setting is unique to the phono preamplifier, andshould be used to compensate for the small imbalances found in

Pagina 17

24setting thecapacitive loadC Load refers to the capacitive load the phono preamplifier presents tothe cartridge. (Of course, any capacitance in the p

Pagina 18

25Installing a Custom LoadA pair of gold plated screw terminals is available inside each of theNº32 phono preamplifier modules. It may be used to inst

Pagina 19 - Customizing Your Nº32

261. Lift connector end of cable out of hole in shield box ifneeded.2. Using the 5⁄64" hex driver, remove four button head screwsfrom top cover o

Pagina 20 - Bal= <-0.0->

275. Loosen each gold thumb screw a few turns.You do not have to remove the thumbscrews—just loosen themenough to slide the leads of your resistor in

Pagina 21

289. Guide cables through holes and replace top cover.10. Re-install top cover screws.Be careful not to cross thread these relatively small screws.11.

Pagina 22 - . For ex

29Care and MaintenanceTo remove dust from the external cabinet of the Nº32, use a featherduster. To remove dirt and fingerprints, we recommend isoprop

Pagina 23 - 1 and for Phono 2

Important Safety InstructionsPlease read all instructions and precautions carefully and completely before operating your MarkLevinson® preamplifier.1.

Pagina 24

30U.S. and Canadian Warranty90-day limited warranty This Mark Levinson® product is warranted to be free from defects inmaterial and workmanship under

Pagina 25 - Installing a Custom Load

31Obtaining ServiceWe take␣ great pride in our dealers. Experience, dedication, and integritymake these professionals ideally suited to assist with ou

Pagina 26

32SpecificationsThe correlation between published specifications and sonic quality is unreliable. A listof numbers reveals virtually nothing. All tech

Pagina 27

33Installation Notes

Pagina 28 - Preamplifier Modules

630357 © 3/1999 Madrigal Audio Laboratories, Inc. All rights reserved. Printed in U.S.A.is a registered trademark of Madrigal Audio Laboratories, Inc.

Pagina 29 - Care and Maintenance

4From all of us at Madrigal Audio Laboratories, thank you for choosing the MarkLevinson Nº32 Reference Phono Preamplifier Modules.A great deal of effo

Pagina 30 - U.S. and Canadian Warranty

5Table of ContentsSpecial Design Features of the Nº32 Reference Preamplifier ... 6modular approach ...

Pagina 31 - Obtaining Service

6Special Design Features of theNº32 Reference Preamplifiermodular approach The Nº32 Reference Preamplifier and Reference Phono PreamplifierModules wer

Pagina 32 - Specifications

7tion, optional custom termination is provided via a pair of gold-platedterminal posts within each phono module. No soldering is necessarywhen using t

Pagina 33 - Installation Notes

8able from our balanced circuitry by including a balanced XLR inputconnector version of the phono preamplifier modules.123NC123NCLEFT +LEFT -TONE ARM

Pagina 34 - MADRIGAL AUDIO LABORATORIES

9width and open loop gain to provide uncompromised performanceeven at the 60db of gain required by a moving coil preamplifier. Theinstrumentation ampl